Raritan Dominion PX Remote Power Management Solutions

Raritan’s family of intelligent rack power distribution units (PDUs) include switched, non-switched and metered PDUs and inline meters.

Raritan Dominion PX Rack Power Distribution Units

Raritan Dominion PX

Dominion PX Feature Snapshot:

  • Multiple Configurations - Outlet type and number, AMP, and Current configurations available in various form factors
  • Circuit breakers - instead of fuses
  • Outlet level control - independent on/off with user configurable power sequencing
  • Local Monitoring - local LED display for hot/cold state, current & voltage metering with alert for overload condition
  • Secure Access - 256-bit encryption (AES) in hardware with access via HTTP/HTTPS/SSH plus built-in Firewall and per outlet access control list
  • Flexible Remote Access Options -  simultaneously access HTML GUI via serial & over IP, Server Management Interface (IPMI), UNIX-like Console interface via serial connector or telnet/SSH
  • Proactive Metering/Monitoring -
    • Per-Outlet Power Metering: Average power consumption, Real RMS power, RMS voltage & current, Apparent power
    • Monitoring Auto Alerts: 2 stages configurable per outlet with buzzer alarm, Email and  SNMP traps

Have Questions? Call 1-800-638-2638.

The Raritan Dominion PX allows users to remotely power on/off, reboot, monitor and control power in the data center. Standard features include outlet-level power metering, secure IP access (256-bit AES encryption), user-configurable power sequencing, and the ability to set warning/shutoff thresholds at the outlet and unit levels. Additionally, the outlet on/off status is retained in the event of power loss restoring power only to those receptacles that were on before the outage. Outlet grouping is available enabling power cycling to servers with redundant power supplies. Raritan's IP clustering feature enables users to daisy chain power strips together.

These intelligent PDUs can be managed with a user-friendly browser interface, or with other interfaces/protocols that might be preferred by IT administrators, including SSH, Telnet, IPMI, and SMASH CLI. The Dominion PX also supports advanced authorization options, including strong password, outlet-level permissions, and support for LDAP/S, RADIUS, TACACS+, and Active Directory.

The Dominion PX can be used as a standalone power management solution or integrated with Raritan Access Solutions such as Dominion KX, SX, or KSX as well as the Paragon II. For centralized management, the PDUs and Access Solutions can be managed through Raritan's CommandCenter Secure Gateway.

The Dominion PX intelligent PDUs are available in 1U, 2U, and Zero U form factors and 8, 12, or 20 available receptacles. Both NEMA and IEC plug-type combinations are available, and the units are certified by most major agencies worldwide.

Below is a sampling of the Dominion PX Screenshots:

Outlets Display

Turn individual outlets OFF and ON and monitor the individual outlets and the rack PDU overall. Each outlet features an icon whose color and flashing status indicates the status of the outlet.

Outlet Details

Displays the current, voltage and power values and status of a specific outlet in real time, and allows the user to power on, off and power cycle the outlet.

Alert Configuration Window

Allows users to set event policies, for example, configure Dominion PX to send an alert if a particular outlet's current draw exceeds the critical threshold set by using the Outlet Setup Window.

The Raritan Dominion PX offers many Features & benefits:

Distribution of power:

  • 8, 12, 20 outlets: NEMA and IEC
  • Amp/Current Options: 15A/120V, 20A/120V, 30A/120V, 30A/208V, Custom configurations available
  • Compliant to new UL 60950 3rd edition
  • Circuit breakers instead of fuses
  • Various form factors (0U, 1U, 2U)

Remote Management Control

  • Independent Outlet Control: On/off, Reboot
  • Power sequencing: User configurable, Delay per outlet, Outlet sequence
  • Retains state of the outlet before an outage
  • Outlet on/off is controlled from the software
  • Local LED console for metering current and voltage (per outlet)
  • Outlet Cold/Hot status on each outlet
  • LED alert in case of overload

Access/Security

  • Secure Access
    • 256-bit encryption (AES) in hardware
    • HTTP/HTTPS/SSH
    • Operates securely in a standalone mode
    • Integrates to external authentication/authorization services
    • Built-in Firewall
    • Built-in access control list
    • User rights per outlet
  • Flexible Remote Access Options for switching, metering, data collection and monitoring:
    • Convenient HTML GUI
    • Can access via serial and IP simultaneously
    • Server Management Interface (IPMI)
    • UNIX-like Console interface via serial connector or telnet/ssh (compatible with SMASH server management )

Proactive Monitoring

  • Per-Outlet Power Metering: Average power consumption, Real RMS power, RMS voltage & current, Apparent power
  • Monitoring Auto Alerts:
    • 2 stages of thresholds: Yellow and red, Both configurable by the user per outlet
    • Buzzer alarm
    • Email
    • SNMP traps
  • Port for External Sensors

Consolidated Management

  • Intuitive HTML GUI with IP connection
  • Consistent with other Raritan interfaces
  • "Per outlet" view and control
  • User rights per outlet

PX-5000 series Outlet metered, outlet switched iPDU Part Numbers:

VACOutletsRack UnitsAmps Per Phase
16203032
12081DPXR8-15DPXR8-20,
DPXR8-20L,
PX-5812
12012ZeroDPXS12-15DPXS12-20,
DPXS12-20L
DPXS12-30L,
DPXS12-30L-J
 
12020Zero DPXS20-20,
DPXS20-20L,
DPXS20-20L-J
DPXS20-30L 
120202 DPXR20-20,
DPXR20-20L
DPXR20-30L 
12024Zero 

PX-5802T

  
3PH
120/
208
24Zero 

 PX2-5561

PX-5652 
3PH
120/
208
30Zero  PX2-5660
PX2-5660-E2
 
20862  PX-5810 
20881 

DPXR8A-20L6, 
DPCR8A-20L6-J, 
PX-5192C

PX-5198 
20816Zero  PX-5384 
20820Zero DPXS20A-20L6DPXS20A-30L6,
DPXS20A-30L6-J,
PX-5464,
PX-5464T
PX2-5464
PX2-5464-E2
 
208202  DPXR20A-20L6DPXR20A-30L6
PX2-5460R-E2
 
20824Zero  PX-5496
PX2-5496
 

240

81DPXR8A-15AU DPXR8A-20AU  
24012Zero DPXS12A-20AU DPXS12A-32AUA
24016Zero   PX-5820,
PX-5820A1,
PX-5820A2
24020Zero DPXS20A-20AU DPXS20A-32AUA, 
PX-5469A2T
24024Zero PX-5635 PX-5501
3PH 20862  PX-5119 
3PH
208
18Zero  

PX-5902T,
PX-5924

 
3PH
208
24Zero PX-5508, PX-5510PX-5520,
PX-5522,
PX-5523,
PX-5524,
PX-5525
 
3PH
400
12ZeroPX-5314,
PX-5315
 PX-5616PX-5318,
PX-5318A2
3PH
400
122   PX-5318A2
3PH
400
18Zero   PX-5341
3PH
400
24ZeroPX-5628I 

PX-5630,
PX-5633,
PX-5550

PX-5528,
PX-5530,
PX-5917,
PX-5917A1,
PX-5917A2

VACOutletsRack UnitsAmps Per Phase
5060
3PH 20862PX2-5940
PX2-5939R
 
3PH
208
18Zero PX2-5941V
3PH
208
24ZeroPX-5532,
PX-5534,
PX-5535
 

PX-4000 Series Outlet Metered iPDU Part Numbers:

VACOutletsRack
Units
Amps Per Phase
2030325060+
20841U PX-4080T   
20881UPX2-4190CR-E2 PX-4198   
20816Zero PX-4384   
20824Zero PX-4496   
3PH
208
6Zero   

PX-4100,
PX-4322

PX-4102
3PH
208
12Zero   PX-4316,
PX-4320
PX-4320
3PH
208
18Zero   PX2-4951YV-E2PX2-4941
3PH
208
24Zero PX2-4508

PX-4520,
PX-4521,
PX-4522,
PX-4523,
PX-4524,
PX2-4525
PX2-4520XV-E2
PX2-4524XV-E2

 

PX-4532,
PX-4534,
PX-4535
PX2-4551V-E2V2

 
3PH
208
36Zero PX2-4725
PX2-4724
   
3PH
240
16Zero  

PX-4820,
PX-4820A1,
PX-4820A2

  
3PH
400
6Zero PX-4120

PX-4104,
PX-4104A1,
PX-4104A2

  
3PH
400
12Zero 

PX-4621,
PX-4633

PX-4307,
PX-4530

  
3PH 40018Zero  PX2-4507  
3PH 400182U   PX2-4913U 
3PH
400
24Zero PX-4630

PX-4530,
PX-4917,
PX-4917A1,
PX-4917A2

  
3PH 40036Zero  PX2-4704U  

PX-3000 Series inline Power Meter Part Numbers:

VACLinesRack
Units
Amps Per Phase
16203032
100-24021U

PX-3211*,
PX-3220**

PX-3211*,
PX-3220**

PX-3220PX-3220
100-24041U

PX-3411*,
PX-3420**,
DPXR4X1A-16NP

PX-3411*,
PX-3420**

PX-3420,
PX-3423

PX-3420
4001Zero    
3PH 380 - 415V1Zero  PX2-3172PX2-3172
3PH 190 - 41521U   PX-3270PX-3270
3PH 190 - 41531U  PX-3370PX-3370

* PX-3211 and PX-3411 operate at either 16A or 20A depending on the cord set chosen.
** PX-3220 and PX-3420 operate at up to 40A (32A rated) per line depending on the wiring in the data center.

PX-2000 Series Metered, outlet switched iPDU Part Numbers:

VACOutletsRack UnitsAmps Per Phase
≤16203032
12081

PX2-2142R
PX2-2145R
PX2-2162R

PX2-2146R
PX2-2147R
PX2-2166R
  
12024Zero PX2-2474
PX2-2475
PX2-2475C
PX2-2476
PX2-2802

PX2-2492
 
20881PX2-2148RPX2-2176R
PX2-2180R
  
20824Zero PX2-2480
PX2-2482

PX2-2496
PX2-2497

 
20836Zero    

240

81PX2-2190R
PX2-2190CR
PX2-2190A4R 
PX2-2190A1R
PX2-2190A2R
PX2-2190A3R
  
24024Zero PX2-2486A4PX2-2486
PX2-2486C
PX2-2486A1
PX2-2486A2
PX2-2486A3
 PX2-2493
PX2-2493A1
PX2-2493A2
PX2-2500
PX2-2500A1
PX2-2500A2
3PH 20824Zero PX2-2510
PX2-2511

PX2-2522
PX2-2523

 
3PH 20836Zero PX2-2735
PX2-2736
PX2-2724
PX2-2725
 
3PH 40024Zero PX2-2516PX2-2627PX2-2633 PX2-2530
PX2-2530A1
PX2-2530A2 
3PH 40036Zero PX2-2732PX2-2737PX2-2731PX2-2730
PX2-2730A1
PX2-2730A2 

PX-1000 Series Metered iPDU Part Numbers:

VACOutletsRack UnitsAmps Per Phase
≤1620303260+
12081PX2-1145R

PX2-1146R,
PX2-1147R

   
12024Zero PX2-1474,
PX2-1475,
PX2-1802
   
20881PX2-1148RPX2-1176R,
PX2-1180R
PX2-1200R   
20824Zero 

PX2-1480,
PX2-1482

PX2-1497
PX2-1497V-E2
  
20836Zero  PX2-1841  

240

81

PX2-1190A1R,
PX2-1190A2R,
PX2-1190A3R,
PX2-1486A4

    
24024ZeroPX2-1486A4

PX2-1486A1,
PX2-1486A2,
PX2-1486A3

 

PX2-1493A1,
PX2-1493A2

 
3PH 20824Zero PX2-1508  PX2-1551
3PH
208
36Zero  

PX2-1724,
PX2-1725,
PX2-1721

  
3PH 20845Zero  PX2-1955  
3PH 40024Zero  PX2-1629  
3PH 40036Zero  PX2-1731

PX2-1730,
PX2-1730A1,
PX2-1730A2

 

Purchasing Options

Is the Raritan Dominion PX the best Power Distribution solution for your power needs?
Data Center Consultation
Our engineers can help you select the best solution for your power needs.
Click here or Call 1-800-638-2638 for a free power project evaluation.

(back to top)