APC Symmetra PX UPS (10 to 500 kVA/kW)A look inside the APC Symmetra PX UPS

The APC Symmetra PX is a redundant, scalable, power protection system designed to cost effectively provide high levels of availability. Seamlessly integrating into today's state-of-the-art data center design, the Symmetra PX is a true modular system. Made up of dedicated and redundant modules--power, intelligence, battery and bypass, all engineered into a design that is easily and efficiently serviceable, this architecture can scale power and runtime as demand grows or as higher levels of availability are required.

Symmetra PX serves as the core power train that drives APC InfraStruXure systems for small and medium data centers but can also power individual "zones" of larger data centers. Highly manageable, the Symmetra PX features self-diagnostic capabilities and standardized modules which mitigate the risk of human error resulting in increased overall data center reliability.

APC Symmetra PX Features:

Availability

  • Configurable for N+1 internal redundancy- Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
  • Redundant Intelligence Modules- Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
  • Power Modules connected in parallel- Enhances availability by allowing immediate, seamless recovery from isolated module failures.
  • Battery modules connected in parallel- Delivers higher availability through redundant batteries.
  • Hot-swappable power modules- Ensures clean, uninterrupted power to protected equipment during Power Module replacement.
  • Hot-swappable intelligence modules- Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.
  • Hot-swappable batteries- Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Modular design- Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
  • Network manageable- Provides remote management of the UPS over the network.
  • Automatic internal bypass- Supplies utility power to the connected loads in the event of a UPS overload condition or fault.

Agility

  • Scalable power capacity- Reduces UPS over-sizing costs today by allowing quick upgrades later.
  • Scalable runtime- Allows additional run time to be quickly added as needed.
  • Front-access servicing- Simplifies installation and maintenance while minimizing space requirements.
  • Programmable frequency- Ensures compatibility with different input frequencies.
  • SmartSlot- Customize UPS capabilities with management cards.
  • Battery replacement without tools- Allows quick, easy battery replacement.

Total Cost of Ownership

  • Fully-rated power kVA equals kW- Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
  • Input power factor correction- Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Generator compatible- Ensures clean, uninterrupted power to protected equipment when generator power is used.
  • Automatic self-test- Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Temperature-compensated battery charging- Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Manageable external batteries- Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
  • Intelligent battery management- Maximizes battery performance, life, and reliability through intelligent, precision charging.

Manageability

  • InfraStruXure Central compatible- Enables centralized management via APC InfraStruXure Central.
  • LCD display- Alpha-Numeric Display which displays system parameters and alarms.
  • LED status indicators- Quickly understand unit and power status with visual indicators.
  • Audible alarms- Provides notification of changing utility power and UPS conditions.

 

 

APC Symmetra MW UPS (400kW to 1.6MW)

The APC Symmetra MW is a modular, fault-tolerant UPS in the 400-1600 kilowatt range. Ideal for large data centers, complete buildings, healthcare and other critical facility protection requirements, the Symmetra MW can be scaled for rigorous and changing electrical demands. Symmetra MW provides increased availability through internal N+1 configurability, predictive failure notification and multi-module paralleling features. Setting a new standard for low cost of ownership Symmetra MW delivers best-in-class efficiency and a reduction in rating of electrical infrastructure- wires, transformers and generators. Slide-in/out power modules, manageable external batteries and self-diagnosing features greatly reduce mean time to repair. Combined with a wide range of line-up and match options Symmetra MW provides a customizable system in a standardized design for any large on-demand network-critical physical infrastructure.

A look inside the APC Symmetra MW UPS

A look inside the APC Symmetra MW UPS System:

  1. Modular, scalable power to right size the UPS to existing and future loads.
  2. Inverter section modules are easily added or replaced by one person
  3. Touch screen LCD displays system status, power flow and metering information
  4. Static Switch is rated for continuous duty @ 125% overload, and 200kAIC withstand rating.
  5. Fault tolerant design insures that individual component failures don't affect the load.
  6. Over 94% efficiency at 25% load.  97% efficiency at full load.

The Symmetra Megawatt II is easily paralleled for increased capacity and/or redundancy. Up to 8 Symmetra Megawatt II units may be paralleled, depending on the availability of adequately sized circuit protection devices.

UPSync is an available option that allows multiple Symmetra Megawatt II modules to maintain synchronous operation regardless of the availability of an input power source while in parallel operation.

MegaTie allows maintenance on connected modules without power interruption to the critical load.

APC Symmetra MW Features:

Availability

  • Configurable for N+1 internal redundancy- Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
  • Power Modules connected in parallel- Enhances availability by allowing immediate, seamless recovery from isolated module failures.
  • Battery modules connected in parallel- Delivers higher availability through redundant batteries.
  • Modular design- Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
  • Battery failure notification- Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Audible alarms- Provides notification of changing utility power and UPS conditions.
  • Network manageable- Provides remote management of the UPS over the network.
  • Generator compatible- Ensures clean, uninterrupted power to protected equipment when generator power is used.

Agility

  • Scalable power capacity- Reduces UPS over-sizing costs today by allowing quick upgrades later.
  • Scalable runtime- Allows additional run time to be quickly added as needed.
  • Parallel-capacity capable- Increases total power capacity by using multiple UPSs simultaneously.
  • Parallel-redundant capable- Power the connected equipment with multiple UPSs to increase system redundancy
  • Multiple cable-entry points- Provides flexibility of UPS placement in the room and easy access to install cabling to the terminal blocks.
  • Front-access servicing- Simplifies installation and maintenance while minimizing space requirements.

Total Cost of Ownership

  • Fully-rated power kVA equals kW- Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
  • Input power factor correction- Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Automatic self-test- Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Temperature-compensated battery charging- Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Manageable external batteries- Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
  • Intelligent battery management- Maximizes battery performance, life, and reliability through intelligent, precision charging.

 

 

APC MGE EPS UPS Systems

APC MGE EPS 6000
(300 kVA to 500 kVA)

The MGE EPS 6000 60Hz continues to be the benchmark of quality and availability for the MGE EPS range of UPS modules in North America. MGE EPS 6000 continues demonstrate its robust design with over 10,000 units installed providing day after day of critical power protection. These models were the first to introduce IGBT inverters and pulse width modulation technology which gained overall system efficiency and a solid 100% step load responses. MGE EPS 6000 has superior flexibility, with auxiliary equipment such as: low kVAR input filters, external maintenance bypass, critical bus synchronization, remote alarm status panels, top entry cabinets, and distribution to meet specific site configurations.

 

APC MGE EPS 6000 UPS

APC MGE EPS 7000
(300 kVA to 500 kVA)

The MGE EPS 7000 UPS features a full front access design and all critical serviceable components reachable within minutes not hours. These UPS modules allow IT and facilities managers to respond to increasing demands placed on power infrastructure in growing facilities by offering N+1 capabilities. MGE EPS 7000 was the first in the industry to incorporate a 100% rated static switch on output of UPS inverter with no mechanical contactors which can age and weaken during UPS operation. Energy efficiency is a key feature for the MGE EPS 7000 with a 93.5% system efficiency at full load and continues at high efficiency levels down to 25% load (93%).

MGE EPS 7000 provides pure flexibility, with auxiliary equipment such as: paralleling gear, external maintenance bypass, critical bus synchronization, bottom entry cabinets boxes, and distribution to meet specific site configuration while maximizing efficiency and output power quality.

 

APC MGE EPS 7000 UPS

APC MGE EPS 8000
(555 kVA to 1100 kVA)

The MGE EPS 8000 is the primary choice in the large data center market with its benchmark on quality and availability, from 555 to 1100kVA in a single box. Relying on advanced 12 pulse rectifier and inverter technologies to restrict total harmonic distortion to less than 5 percent. Copper galvanic isolation is provided for both input and output to the UPS while isolating the DC ground from upstream devices in the event of a ground fault condition due to battery leakage. The MGE EPS 8000 is a true high performance machine with efficiency up to 93.5% while maintaining efficiency of 92% at 25% load. UPS delivers clean reliable power even in the harshest of electrical environments.

Featuring 100% step-load capability which ensures a fast response to load changes with accurate voltage regulation. In addition, the MGE EPS 8000 incorporates fault tolerant circuitry that protects the UPS from accidental short circuits usually caused by load side failures or overloads. Core MGE EPS is equipped with a 100 percent rated output static switch with a stable, reliable, predetermined response time. Low carbon footprint and full front access with zero electromechanical connections at the rear of the unit allows the unit to be installed against the wall.

 

APC MGE EPS 8000 UPS

Features & Benefits:

Compatibility

  • Parallel capability- Multiple units can be placed in parallel to meet power capacity and redundancy requirements
  • Output synchronization to external source- UPS can be synchronized with any other independent source to use downstream static transfer switches

Availability

  • High availability architecture- Different running modes: hot stand-by, integrated parallel, or centralized static switch for multi-modules leading to availability architectures

Manageability

  • Intuitive monitoring- Step by step navigation and menu screens for critical system information and data.  Information is easy to access and presented in a very intuitive way.

 

 

APC MGE Galaxy UPS Systems

APC MGE Galaxy 5000
(20 - 120kVA (400V), 50 - 130kVA (480V))

The APC MGE Galaxy 5000 offers technology that increases performance and reliability. Online technology fully isolates and protects against all power quality disturbances. The upstream harmonics management allows a generator friendly installation and flexible configurations for even the most demanding designs.

The MGE Galaxy 5000 offers features such as paralleling capability for both capacity and redundancy, full front access, included start up for ease of serviceability, user friendly graphical display with multiple language options, and SNMP with network based power management options.

 

APC MGE Galaxy 5000 UPS

APC MGE Galaxy 3500
(10 - 30 kVA (208V), 10 - 40 kVA (400V))

The APC MGE Galaxy 3500 offers centralized 3 phase power protection with the reliability of the MGE product family. Ideal for commercial and technical facilities as well as industrial applications, the MGE Galaxy 3500 includes dual-mains input, automatic and maintenance bypasses, and scalable runtime with hot-swappable batteries for increased availability. The parallel capability for redundancy and capacity, new optional bypass panels, and extended run battery frames provide increased flexibility. Low cost of ownership is achieved through best-in-class efficiency and a reduction in rating of electrical infrastructure - wires, transformers, and generators.

The built in Network Management Card with temperature monitoring provides remote monitoring and management through a simple Web/SNMP interface. Serviceability is greatly enhanced by user-replaceable batteries, front access servicing, and included start-up service for maximized configurability.

APC MGE Galaxy 3500 UPS

APC MGE Galaxy 4000
(40 - 75kVA)

MGE Galaxy 4000 offers centralized 3 phase power protection with the reliability of the MGE product family. Ideal for small to medium data centers, facilities and transportation, the MGE Galaxy 4000 offers on-line double conversion technology for true isolation between input and output. Availability is achieved through zero transfer time for critical loads.

The Network Management Card with temperature monitoring provides remote monitoring and management through a simple Web/SNMP interface and provides integration with InfraStruXure Central. Serviceability is greatly enhanced by front panel access and includes start-up service for increased configurability.

 

APC MGE Galaxy 4000 UPS

APC MGE Galaxy PW
(150 - 225kVA)

MGE Galaxy PW offers traditional 3 phase power protection with the reliability of the MGE product family. Ideal for small to medium data centers, facilities and transportation, the MGE Galaxy PW offers on-line double conversion technology for true isolation between input and output. Availability is achieved through zero transfer time for critical loads.

Manageability is achieved with the Network Management Card that provides remote monitoring and management. Serviceability is greatly enhanced by front panel access and includes start-up and standard on-site warranty services.

APC MGE Galaxy PW UPS

APC MGE Galaxy UPS Features & Benefits: (varies depending on MGE Galaxy family)

Availability

  • Dual mains input- Increases availability by allowing the UPS to be connected to two separate power sources.
  • Adjustable voltage sensitivity- Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
  • Frequency and voltage regulation- Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
  • Generator compatible- Ensures clean, uninterrupted power to protected equipment when generator power is used.
  • Parallel-capacity capable- Increases total power capacity by using multiple UPS's simultaneously.
  • Parallel-redundant capable- Power the connected equipment with multiple UPS's to increase system redundancy
  • Cold-start capable- Provides temporary battery power when the utility power is out.
  • Hot-swappable batteries- Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

  • Advanced electrical features- Excellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high efficiency
  • Automatic internal bypass- Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
  • Power conditioning- Protects connected loads from surges, spikes, lightning, and other power disturbances.

Serviceability

  • Front-access servicing- Simplifies installation and maintenance while minimizing space requirements.
  • Multiple levels of service- With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like APC to do for you.
  • 7x24 telephone technical support- Our experienced technical support representatives are available to answer your questions 24 hours a day, 7 days a week, giving you peace of mind knowing the help you need is there when you need it, where available.
  • User-replaceable air filters- Enables quick and simple replacement of air filters.
  • Battery replacement without tools- Allows quick, easy battery replacement.

Manageability

  • Network manageable- Provides remote management of the UPS over the network.
  • Integrates with InfraStruXure Central- An IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
  • Multiple distribution options- Superior design flexibility enables a wide range of customer requirements to be addressed.
  • LCD graphics display- Text and mimic diagrams that display modes of operation, system parameters and alarms.
  • LED status indicators- Quickly understand unit and power status with visual indicators.
  • Built-in Web/SNMP management- Full-featured management via a Web browser as well as comprehensive management from a Network Management System.
  • Environmental Monitoring- Prevent equipment failure from a full range of threatening environmental conditions.
  • Audible alarms Provides notification of changing utility power and UPS conditions.

Total Cost of Ownership

  • Input power factor correction- Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Excellent footprint- Small UPS footprint provides maximum usage of valuable electrical room floor space
  • Temperature-compensated battery charging- Prolongs battery life by regulating the charge voltage according to battery temperature.

 

Is APC UPS the best UPS solution for your data center needs?
Data Center Consultation
Our engineers can help you select the best UPS solution for your data center needs.
Click here or Call 1-800-638-2638 for a free data center project evaluation.

 

 
 About 42U Contact Us Careers Copyright Privacy Policy Site Map
Follow us on:
 Follow 42u on Twitter Subscribe to 42U's channel on YouTube View 42u's profile on slideshare
Copyright © 2015 42U. All Rights Reserved
42U | Phone: 1-800-638-2638 | http://www.42u.com/


APC UPS Power Systems