Liebert MPH - Liebert Managed Rack PDU

Liebert MPH is a flexible Rack PDU solution with remote monitoring and control capabilities as well as environmental input options. It offers multiple power input selections and output configurations in both vertical zero-U and rackmount form factors.  Up to four Liebert MPH PDUs may be interconnected as a Rack PDU Array, consolidating user IP connections and device monitoring.

Liebert MPH Monitoring And Control Support

Monitored electrical parameters include: voltage, current, real and apparent power, power factor, and accumulated energy or consumption. Capacity based current thresholds provide comprehensive alarm notifications from the Rack PDU and branch.

Liebert MPH Can Benefit Your Data Center

  • Monitors electrical and environmental parameters with set threshold and alarm tools
  • Controls access of receptacle power
  • Controls and manages individual receptacles and/or groups of loads and devices
  • Allows you to predict failing conditions before they occur and proactively manage connected equipment for maximum uptime
 

Liebert MPH Managed Rack PDU Installation Example

 
 With single or three phase power input, the Liebert MPH PDU provides output as single phase power and is offered in vertical, Zero U and rack mount form factors to support mounting in 19” EIA 42U rack environments. 

Liebert MPH offers multiple power input selection and output configurations. 1-phase 120 or 208VAC and 3-phase 120/208VAC 20 or 30 amp input power; 1-phase output power including mixed receptacles. Modular card-based communications. Vertical (Zero U) or Rackmount configurations. Up to four Liebert MPH PDUs may be interconnected as a Rack PDU Array, consolidating user IP connections and device monitoring.

  • Liebert MPH Monitored (MPH-NB)- Monitoring only version - provides local and remote monitoring of individual PDU volts, amps, watts, and kilowatt-hours.

  • Liebert MPH Monitored and Controlled (MPH-NC)- Monitoring and controlled version - provides the same features and functionality as the MPH-NB series with the additional capability of remote on/off control of individual receptacles. Local receptacle power on-off status is provided through an LED display.

Is the Liebert MPH Managed PDU the best Rack PDU for your power needs?
Data Center Consultation
Our engineers can help you select the best Rack Power Distribution Unit for your power needs.
Click here or Call 1-800-638-2638 for a free data center power project evaluation.
 

Liebert MPH Managed Rack PDU
Liebert MPH
Managed Rack PDU

The Liebert MPH PDUs offer many benefits:

Flexibility:

  • Local displays are easily located to suit a crowded and changing rack environment
  • Supports mounting in 19” EIA, 42U rack environments-
    Offered in vertical, zero U and rackmount form factors
  • Provides a compatible monitoring platform for Liebert MPH and Liebert MPX, offering seamless common operation if deployed together
  • User positioned input power cord interface

Higher Availability:

  • Controls and manages individual receptacles
  • Predicts overcurrent conditions before they become critical
  • Shuts down non-essential equipment during power outages to maximize availability and back-up power
  • Expanded branch overload protection minimizes threat of cascading PDU overload
  • Industry leading operating temperature-up to 55˚C / 131˚F to support hot Internal rack environments

Lowest Total Cost Of Ownership:

  • Provides full featured monitoring and control in
    a cost effective package
  • A Rack PDU Array shares a single IP address for up to four Rack PDUs, making deployment faster and easier
  • Energy and power metering provides users the information to maximize the data center power and cooling infrastructure
  • Employs energy efficient receptacle control technology


 

 