| Liebert MPX Rack PDU provides hot-swappable power modules and reconfigurable input power modules, allowing immediate onsite configuration of rack power to suit IT equipment needs. The system offers remote monitoring and control to the receptacle level, as well as monitoring of environmental input options, such as rack temperature and humidity. A modular communications card allows a variety of monitoring options. Liebert MPX Benefits: - Adaptive capacity, distribution, monitoring, control and management of critical devices
- Flexibility to respond to constant change
- Buy only what you need and build on your investment
- Secure communication
Liebert MPX Rack PDUs are available with the following attributes: - 1-phase 120 or 208 VAC and 3-phase 208-240 VAC 20-60 Amp input power
- 1-phase output power including mixed receptacles
- Vertical (Zero U) configuration
- Up to four Liebert MPX PDUs may be interconnected as a Rack PDU Array, consolidating user IP connections and device monitoring.
Liebert MPX allows you to add or change distributed power without powering down. The hot-swappable receptacle modules allow for easy upgrading, and get IT equipment online quickly. Change input power configuration to support dynamic environments while maintaining distribution and communications infrastructure. | | 
| | | | Scalable Design Allows Onsite Configuration To Fit immediate IT Equipment Needs. The Liebert MPX Adaptive Rack PDU features essential characteristics to support fastpaced, growing data centers. | |
Is the Liebert MPX Adaptive PDU the best Rack PDU for your power needs?
 Our engineers can help you select the best Rack Power Distribution Unit for your power needs. Click here or Call 1-800-638-2638 for a free data center power project evaluation. |  Liebert MPX Adaptive Rack PDU
The Liebert MPX PDUs offer many benefits: Flexibility: - Allows user to add individual hot-swappable modules for capacity as demand grows
- Offers the ability to change input capacity or configuration while maintaining Rack PDU infrastructure
- Provides for user located local and remote monitoring and management of connected loads
- Change monitoring and control functionality or mix on a single MPX to suit requirements.
- Position input power module for top or bottom rack entrance.
Higher Availability: - Controls and manages individual receptacles and or groups of loads and devices
- Predicts overcurrent conditions before they become critical
- Shuts down non-essential equipment during power outages to maximize availability and back-up power
- Expanded branch overload protection minimizes threat of cascading PDU overload
- Reliably delivers connected UPS power to the protected equipment
Lowest Total Cost Of Ownership: - Provides the most cost-effective design available-build, add on, or modify the platform design
- Allows redeployment of modules to suit changing needs
- Energy metering provides users the information to maximize the data center power and cooling infrastructure
- Liebert MPX modularity and flexibility extends the useful life of the infrastructure investment
- Employs energy efficient receptacle control technology
Designed for Critical Environments: - Industry leading operating temperature-up to 55˚C / 131˚F to support hot Internal rack environments
- Accurate power metering of +/-1% voltage & current for assured oversight
- Energy and power metering down to the individual receptacle
- Comprehensive alarming including notification of overloaded branch circuits
- Environmental sensing with threshold and alarm set-points
- Notification on the loss or removal of individual rack equipment loads

|