42U.com - Home

Avocent PM1000 / PM2000 / PM3000
Outlet Monitoring PDUs

Avocent PM1000 / PM2000 / PM3000
Power Monitoring and Management


Server Room Evaluation

42U Partial Client List
20-Years of Customer Astonishment!

Energy Efficiency Calculator
Efficiency Calculator


Free Project  Consultation

 
    
Request Price Quote
 Request Quote

Request Quote

 
Project Evaluation
 Project Evaluation

Free Project
Evaluation

 
Free Product Evaluation
 Free Product Evaluation

Free 30-Day
Product Eval

 
 
 
 

Avocent PM1000 /PM2000 /PM3000 Remote Power Management and Remote Power Monitoring

The Avocent PM PDUs include single-phase and three-phase models that support strip-level metering, outlet-level metering or outlet-level metering and switching.  This advanced family of rack PDUs includes horizontal and vertical models for a variety of rack configurations in branch and remote offices.

The PM PDUs include an LED display and a built-in browser interface for local and remote access to real-time data. The metering features, along with the capability to set custom thresholds, allow companies to optimize their electrical infrastructure, without the risk of downtime due to overloaded circuits.

The PM 1000 PDUs enable companies of all sizes to accurately measure the current, voltage and power for the entire strip and the circuits within. The PM 2000 and PM 3000 PDUs take this a step further to support outlet-level metering and switching capability (PM 3000 PDUs only) to provide data center professionals the tools they need to monitor, measure, reduce and manage the growing power consumption costs of IT equipment.

All of these PDUs include advanced features that consist of a built-in network port for access to the browser interface, daisy chain ports for easy installation and expansion and support for external environmental sensors.

Avocent PM2000/PM3000 Application Diagram
Avocent PM2000 / Avocent PM3000 Application Diagram

Avocent PM Features and Benefits:

  • Outlet-Level, Phase-Level and Strip-Level Metering with Threshold/Alert Capabilities – Provides preemptive notification of any impending overload issues before they occur and simplifies the task of installing new equipment Note - measurement resolution +/- 5%
  • Capability to Remotely Switch Outlets Through Onboard Web Interface, DSView Management Software – Allows power to hung up IT equipment to be recycled, turned on or turned off remotely for faster resolution time (not available on PM 1000 or PM 2000 PDUs)
  • Onboard Web Interface – Can be installed for direct access right out of the box or it can be configured as part of a larger integrated solution using the DSView 3 management software
  • IP and Serial Interface Options – Options to install by connecting directly to the network or save IP connections by using the serial interface to connect directly to Avocent appliances already connected to the network
  • Daisy Chaining – Saves the number of IP addresses or console/KVM ports that are required to manage all power distribution needs
  • Integration with DSView 3 Management Software – Single interface for management of IT equipment and PDUs simplifies mapping of outlets to servers and other equipment in order to reduce and minimize power cycling the wrong equipment
  • Integration with DSView 3 Software Power Manager Plug-In – Track historical trends to measure and monitor IT power consumption, capacity and cost in order to understand what issues exist and to make more informed decisions in the future
  • Electronic Overcurrent Protection (OCP) – An added layer of protection that is activated in the event of minor overloads; during such events, outlets are turned off first instead of the primary OCP tripping
  • Sequential Startup – Protects integrity of all upstream electrical infrastructure by staggering the inrush current draw of all plugged-in devices
  • Supports Environmental Sensors – Chain up to six environmental sensors per PDU to measure and monitor temperature and humidity at several different points within the rack for notification of any impending environmental issues

Is the Avocent PM the best Outlet Power Monitoring solution for your power needs?
Data Center Consultation
Our engineers can help you select the best solution for your remote power needs.
Click here or Call 1-800-638-2638 for a free power project evaluation.

Avocent PM Feature Snapshot:

  • Measure and monitor voltage, current, power (kW) and energy (kWh) consumption
  • Create thresholds to generate alerts/notifications
  • Remote switching capability to power on/off outlets (PM 3000 PDU models)
  • Flexible installation - IP and serial interface options
  • Chaining option allows multiple PDUs to share an IP or serial connection
  • Supports external, environmental sensors for measuring temperature and humidity
  • Onboard data log for individual PDU activity logs and historical data
  • Can be managed directly or integrated with other Avocent solutions using the DSView 3 management software
  • Optional DSView 3 software Power Manager plug-in for historical reporting across multiple PDUs

 