Rittal LCP Inline In-Row High Density Cooling System

Rittal's LCP Inline brings data center cooling to the rack level, utilizing chilled water in a closed-loop configuration to prevent heat loss and eliminate hot spots, providing up to 30 kW of useful cooling output. Using Rittal's Liquid Cooling Packages have been proven to reduce energy consumption in data center cooling by 30-45%, making them the perfect addition to the environmentally conscious data center.

Rittal LCP Inline Touchscreen Display

Touchscreen display- as standard, for
monitoring and settings

Rittal LCP Inline Optional Front Cover

Front Cover- The optional front cover, together with the built-in filter fleece, ensures an even air outlet at the sides as well, reduces the air outlet speed, and therefore minimizes draught effects.

The Rittal LCP Inline achieves maximum performance and efficiency in conjunction with Rittal cold aisle containment. With this product combination, a raised floor is not necessary.

 

Rittal LCP Inline Installed within Cold Aisle Containment

 
 Application Example: Combination of LCP Inline and cold aisle containment
  1. LCP Inline
  2. Cold aisle containment
 

Rittal LCP Inline Features:

  • Up to 30kW cooling output
  • Combines the compact design of the LCP with the function of room air-conditioning.
  • High Performance heat exchanger with uniform temperature distribution
  • Controller with networking capability, compatible with all common communication standards (SNMP, Bacnet etc.).
  • Climate control technology, specially designed for IT environments with comprehensive monitoring functions.
  • Frame based on the Rittal TS 8 server cabinet system.

 

Is the Rittal LCP Inline the best high density solution for your cooling needs?
Data Center Consultation
Our engineers can help you select the best high density solution for your cooling needs.
Click here or Call 1-800-638-2638 for a free high density cooling project evaluation.

Rittal LCP Inline
Rittal LCP Inline
High Density Cooling System

The Rittal LCP Inline offers many benefits:

Potential Energy Savings
  • Reduce the need for traditional data center climate control and provide the same heat removal capacity for much lower energy usage by utilizing the "Free Cooling" capacity of existing climate control systems.
Flexibility
  • The capability to cool one or two cabinets from a single LCP or LCP Plus system, depending on potential heat loads.

Expandable

  • Providing a scalable system that can grow as the IT installation grows with modular units that provide simple connections to existing facility infrastructure.

Redundancy

  • Can provide multiple levels of redundancy to meet the most demanding installation criteria from N+1 to 2N and beyond.

 

 

 