Close-coupled, chilled water cooling for medium to large data centers (up to 70kW) InfraStruXure InRow RP is a high capacity precision air conditioning unit designed to maximize sensible cooling for high efficiency operation. The InRow RP product increases the capacity range for chilled water applications and includes an air cooled solution. Both the chilled water and air cooled products offer the ability to control humidity with canister humidifiers and electric reheat, enabling data center designers to leverage the InRow Architecture for both sensible cooling of the IT load in the row, and humidity control of the entire data center. The in-row concept closely couples cooling with the heat load, preventing exhaust air recirculation to sensitive IT equipment. The energy-efficient design lowers total cost of ownership by monitoring IT equipment inlet temperatures to modulate capacity based on the demand for cooling. Fan speed is controlled based on the demand to reduce energy consumption during off-peak cooling periods. The modular, scalable solution improves agility by enabling you to add cooling as demand increases, making the InRow RP ideal for small to large data centers. APC RP Features: - Humidity is managed through a self contained steam canister humidifier for maximum efficiency and ease of maintenance
- Modular design provides scalable solutions to add cooling as demand increases
- Variable speed fans reduce energy consumption during off-peak cooling periods
- Rack inlet control guarantees inlet temperature to IT equipment
A look inside the APC RP
Humidifier The humidifier is a self-contained, steam-generating type, factory piped and wired, with a disposable cylinder and an automatic solid state control circuit. Humidifier canisters are replaceable. The humidifier controller communicates directly to the microprocessor controller and provides complete status and control at the operator interface. Room Air Distribution Row-based systems are placed in line with rack enclosures. At least one system is used per hot aisle. Air is drawn in through the rear of the system, cooled, and discharged into the cold aisle, thereby neutralizing the sensible heating effects of the data processing equipment. The InRow RP delivers high volumes of airflow to eliminate hot spots in densely populated environments. Variable speed fans The InRow RP unit is equipped with variable speed, electrically commutated, 400-mm (15.8-in) backward incline, direct drive fans. The chilled water unit is equipped with three fans while the air-cooled unit has two. In order to provide uniform airflow over the cooling coil, the fans provide a draw-through air pattern. Fans are easily serviced in the field. Microprocessor controller The microprocessor controller is standard on each system. The controller provides precision control for the demanding requirements of: - Computer rooms
- Telecommunication facilities
- Clean rooms
- Power equipment
- Medical equipment rooms
- LAN/WAN environments
The easy-to-use display allows the operator to select options from the device's menu-driven interface to control and monitor the connected air conditioning system. Is the APC RP the best high density solution for your cooling needs?
Our engineers can help you select the best high density solution for your cooling needs. Click here or Call 1-800-638-2638 for a free high density project evaluation. | APC RP High Density Cooling System
The APC RP offers many benefits: Availability:- Predictable cooling- Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
- Dual A-B Power Inputs- Draws power from the UPS for power protection with dual feeds for redundancy.
- Rack inlet control- Rack inlet control guarantees inlet temperature to IT equipment.
- Top and bottom chilled water connections- Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
- Active response controls- Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Total Cost of Ownership:- Variable speed fans- Variable speed fans reduce energy consumption during off-peak cooling periods.
- Row-based architecture- Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Agility: - Modular design- Modular design provides scalable solutions to add cooling as demand increases.
- Scaleable densities- Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.
- Casters- Provides flexibility to move the unit to wherever cooling is required.
Serviceability: - Easy service access- In-row equipment allows for all serviceable components to be replaced/maintained in the hot or cold aisle.
Manageability: - Real-Time Capacity Monitoring- Real-time display of current and available cooling.
- Microprocessor controller- Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
- Building Management System Integration- Send alarms and data points allowing you to manage critical building infrastructure from a single system.
|